Room Control for VAV Applications
The iSMA CONTROLLI Touch Point VAV 2.0 room operating unit provides local temperature setpoint and occupancy control for rooms where airflow or fan operation is handled automatically by the connected controller or BMS.
Unlike the standard Touch Point 2.0 model, the VAV version does not include dedicated fan-control buttons. This gives occupants a simpler interface while allowing the room or zone controller to manage the underlying HVAC application.
Sensor values, setpoint adjustments and occupancy commands are exchanged with the connected control system over BACnet MS/TP or Modbus RTU/ASCII.
Key Features
- Three-button capacitive interface for occupancy and temperature setpoint adjustment
- Temperature sensor fitted as standard
- Optional humidity and CO2 sensing configurations
- High-CO2 alarm functionality on models with a CO2 sensor
- 0.96-inch TFT display with three backlight-intensity modes
- Occupancy, ECO, heating and cooling LED indication
- Freely configurable RGB navigation LED
- BACnet MS/TP and Modbus RTU/ASCII, selected using a DIP switch
- Two Smart Plug™ RJ45 ports combining power and RS485 communication
- Daisy-chain connectivity for additional panels
- Removable screw terminals for direct power and RS485 connection
- Configuration through USB-C using the free iSMA Configurator
- Black or pure-white glass finish
- Suitable for a standard 60 mm European wall box or US 1-gang box
Touch Point VAV 2.0 Model Selection
Every model includes a display and temperature sensor. Humidity and CO2 sensing can be added individually or together, with each configuration available in black or white.
| Sensor configuration | Black model | White model |
|---|---|---|
| Temperature | TP-VAV-DISP-B-2 | TP-VAV-DISP-W-2 |
| Temperature and CO2 | TP-VAV-C-DISP-B-2 | TP-VAV-C-DISP-W-2 |
| Temperature and humidity | TP-VAV-H-DISP-B-2 | TP-VAV-H-DISP-W-2 |
| Temperature, humidity and CO2 | TP-VAV-HC-DISP-B-2 | TP-VAV-HC-DISP-W-2 |
Smart Plug™ Installation
Two Smart Plug™ RJ45 connections combine power and RS485 communication in one connection. This supports daisy-chained installation and allows the panel to be powered directly from compatible controllers equipped with Smart Plug™.
A removable screw connector is also provided for conventional power and RS485 wiring.
Communication and Configuration
The panel supports BACnet MS/TP and Modbus RTU/ASCII communication over its RS485 interface. The required protocol can be selected using the hardware DIP switch.
Configuration is completed using the free iSMA Configurator through the USB-C port. Settings can also be accessed through Modbus registers or BACnet objects, supporting integration with the wider room-control application.
Technical Specifications
| Power supply | 20–40 V DC or 24 V AC ±20% |
|---|---|
| Power consumption | 0.6 W at 24 V DC or 1.9 VA at 24 V AC |
| Communication | BACnet MS/TP or Modbus RTU/ASCII |
| RS485 capacity | Up to 128 devices |
| Communication ports | Two Smart Plug™ RJ45 ports and one removable screw connector |
| Baud rate | 2400–115200 bps |
| Display | 0.96-inch TFT |
| Temperature sensor | 0–50°C range; ±0.5°C accuracy; 0.1°C resolution |
| Humidity sensor | 0–100% RH range; ±2% RH accuracy between 10% and 90% RH |
| CO2 sensor | 400–2000 ppm range; accuracy of ±(50 ppm + 5% of reading) |
| Ingress protection | IP20 for indoor installation |
| Dimensions | 86 × 86 × 14.8 mm |
| Finish | Black or white glass front |
Humidity and CO2 specifications apply only to models fitted with the corresponding sensors.
Controller Integration
Touch Point VAV 2.0 connects to a compatible room or zone controller over BACnet MS/TP or Modbus RTU/ASCII. The manufacturer’s application example shows the panels operating within systems incorporating RAC18-IP, VAV14-IP and ZAC24-IP-D controllers.
Technical Literature
The shared hardware and software user manuals for the complete family are available on the Touch Point 2.0 range page.
Explore the Touch Point 2.0 Range
This model is designed for VAV and other comfort-control applications where fan operation does not require dedicated room-panel buttons. For fan-coil control, distributed sensing, combined HVAC and room automation, or dedicated lighting and blind control, explore the complete Touch Point 2.0 range.