The ONICON F-4300 Clamp-on Ultrasonic Flow Meter provides a permanent measurement point in full, pressurised pipes where cutting into existing pipework, interrupting live services or introducing additional pressure loss would create unnecessary project friction. Its matched, non-wetted transducers use differential transit-time technology to measure liquid flow through the pipe wall.
This makes the F-4300 particularly relevant to consultants specifying retrofit measurement, system integrators connecting permanent flow data to the BMS, M&E contractors working around operational plant and facility or energy teams that require continuous data for monitoring and performance analysis.
F-4300 Clamp-on Ultrasonic Flow Meter Applications
- Permanent flow measurement in existing chilled water, heating hot water and condenser water systems
- Retrofit projects where pipe cutting or a system shutdown is impractical
- Continuous baseline monitoring of hydronic system demand and performance
- Boiler feed, domestic water and other relatively clean liquid applications
- Flow validation and ongoing monitoring through a BMS or BAS
- Bi-directional flow measurement in full, pressurised pipes
- Thermal energy measurement using matched supply and return temperature sensors
Why Specify the F-4300 Clamp-on Ultrasonic Flow Meter?
Permanent measurement without pipe penetration
The ultrasonic transducers are secured to the outside of the pipe, allowing the F-4300 to be installed without drilling, cutting or inserting a sensor into the liquid stream. The installation introduces no additional pressure drop and can avoid the shutdown and associated coordination required for an inline or insertion meter.
Designed for difficult retrofit conditions
The F-4300 is suited to existing systems where access, operational continuity or pipework condition makes a conventional meter difficult to install. Three transducer series cover pipe sizes from ½ to 48 inches, with mounting hardware selected for the specified pipe size and application.
Configured for the intended application
Each meter is individually configured and programmed using the customer’s application data before delivery. The relevant pipe material, pipe size, fluid and operating conditions should therefore be confirmed during product selection. This reduces complex field programming while giving commissioning engineers a defined set of application parameters to verify on site.
Measurement Performance and Pipe Suitability
The F-4300 measures flow using matched ultrasonic transducers operating through the wall of the pipe. It is intended for relatively clean liquids in full pipes and supports a wide range of metallic and non-metallic pipe materials.
- Pipe-size range from ½ to 48 inches, according to the selected transducer series
- Bi-directional fluid velocity range from 0.07 to 40 ft/s
- Accuracy of ±1% of reading from 1.5 to 40 ft/s
- Accuracy of ±0.015 ft/s at velocities below 1.5 ft/s
- Repeatability and linearity of ±0.25%
- Fluid temperature range from -40°F to 300°F
Actual measurement performance depends on the pipe remaining full and on the suitability of the selected location. Pipe material, wall thickness, surface condition, transducer position and available straight pipe must all be considered during design and commissioning.
BMS Integration and Onboard Data
The flow-only F-4300 provides one isolated analogue output and two programmable digital outputs. Its RS485 interface can be configured for native BACnet MS/TP or Modbus RTU communication, allowing flow and total data to be incorporated into the building management system without a separate protocol gateway. Modbus TCP/IP is also available as an option with the applicable 24 VDC configuration.
A built-in 128 MB data logger can store up to approximately 26 million data points. Recorded information can be retrieved through the USB connection, providing facility and energy teams with a permanent source of baseline and trend data without relying solely on the BMS front end.
The NEMA 4X/IP67 polycarbonate enclosure incorporates a backlit display and five-button keypad for local readings, programming, commissioning and diagnostics. Available input-power options include 24 V AC/DC and 110–240 VAC.
F-4300 Thermal Energy Measurement Option
The F-4300 can also be specified as a thermal energy measurement system. In this configuration, the meter combines clamp-on ultrasonic flow measurement with a matched pair of high-precision supply and return temperature sensors to calculate the energy transferred through a heating or cooling circuit.
The thermal energy version expands the available inputs and outputs to support flow, energy and temperature data. It can provide three isolated analogue outputs, three digital inputs and six programmable digital outputs, alongside BACnet MS/TP, Modbus RTU or the applicable Modbus TCP/IP communications option.
Temperature-sensor and thermowell arrangements should be selected for the pipe size, application temperature and installation requirements. Clamp-on thermowells are available for projects where avoiding pipe penetration remains part of the design requirement.
Installation and Commissioning Considerations
The F-4300 removes the need to penetrate the pipe, but correct site selection remains essential. The pipe must be full, the transducers must be mounted in the prescribed position and adequate straight pipe should be provided upstream and downstream wherever possible.
Before ordering and commissioning, the project team should confirm:
- Pipe material, nominal size, outside diameter and wall thickness
- Fluid type, operating temperature and expected flow range
- Available upstream and downstream straight pipe
- Pipe surface condition and the proposed transducer position
- Required analogue, digital and network outputs
- Input-power supply and transducer cable length
- Whether flow-only or thermal energy measurement is required
The supplied calibration certificate and application configuration should be checked against the actual installation before the meter is commissioned. Transducer cables should be installed in dedicated conduit and separated from power or other signal wiring in accordance with the installation guide.
F-4300 Enclosure and Mounting Dimensions
The F-4300 enclosure measures 7.50 inches wide by 11.00 inches high. The mounting-hole centres are spaced 6.46 inches horizontally and 10.00 inches vertically.
![]()
Need Portable Flow Testing Instead?
The F-4300 is intended for permanent installation and continuous monitoring. For temporary testing, system validation, test and balance work or short-term baseline monitoring, view the ONICON FP-4400 Portable Clamp-on Ultrasonic Flow Meter.
Product Downloads
- ONICON F-4300 Clamp-on Ultrasonic Flow Meter Datasheet
- ONICON F-4300 Guide Specification
- ONICON F-4300 Submittal and Data Sheet
- ONICON F-4300 Installation and Operation Guide
- ONICON F-4300 Thermal Energy Measurement System Installation and Operation Addendum
- ONICON F-4300 Clamp-on Thermowell Installation Instructions
- ONICON F-4300 Hardware and Transducer Update Procedure
Available Through IBC
The ONICON F-4300 is available through IBC for permanent commercial HVAC flow and thermal energy measurement applications. For more information, assistance confirming pipe and application suitability or to discuss project pricing, consultants, system integrators, M&E contractors and facility teams are invited to contact IBC directly.